4 April 2012
Nuclear Spent Fuel Storage Installation Error
[Federal Register Volume 77, Number 65 (Wednesday, April 4, 2012)]
[Notices]
[Pages 20438-20440]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: 2012-8114]
-----------------------------------------------------------------------
NUCLEAR REGULATORY COMMISSION
[Docket Nos. 72-1030, 72-56; 50-338 and 50-339: NRC-2012-0084]
Independent Spent Fuel Storage Installation, Virginia Electric
and Power Company: North Anna Power Station Units 1 and 2
AGENCY: Nuclear Regulatory Commission.
ACTION: Issuance of an environmental assessment and finding of no
significant impact.
-----------------------------------------------------------------------
FOR FURTHER INFORMATION CONTACT: Jennie Rankin, Project Manager,
Division of Spent Fuel Storage and Transportation, Office of Nuclear
Material Safety and Safeguards, U.S. Nuclear Regulatory Commission,
Washington, DC 20555. Telephone: (301) 492-3268; Fax number: (301) 492-
3342; email: jennivine.rankin@nrc.gov.
SUPPLEMENTARY INFORMATION:
I. Introduction
The Nuclear Regulatory Commission (NRC or Commission) is
considering issuance of a one-time exemption to Virginia Electric and
Power Company (Dominion or licensee) pursuant to 10 CFR 72.7 from the
requirements of 10 CFR 72.212(b)(3) and the portion of 72.212(b)(11)
which requires compliance with the terms, conditions, and
specifications of the CoC. Dominion submitted its exemption request by
letter dated July 21, 2011, as supplemented September 28, 2011.
Dominion has loaded spent nuclear fuel into Transnuclear, Inc. (TN)
NUHOMS[supreg] HD Storage System (HD-32PTH) dry storage casks, under
the Certificate of Compliance (CoC or Certificate) No. 1030, Amendment
No. 0. The licensee inadvertently reversed the upper and lower zones
while preparing the dry shielded canister (DSC) loading maps. This
resulted in twelve fuel assemblies being loaded into seven DSCs with
decay heat greater than the levels specified in the CoC. Dominion
requests a one-time exemption to the 10 CFR part 72 requirements to
continue storage of the affected DSCs with serial numbers DOM-32PTH-
004-C, -005-C, -007-C, -010-C, -013-C, -019-C and GBC-32PTH-011-C in
their current condition at the Independent Spent Fuel Storage
Installation (ISFSI) associated with the operation of Dominion's
nuclear power reactors, North Anna Power Station Units 1 and 2, located
in Louisa County, Virginia.
II. Environmental Assessment (EA)
Identification of Proposed Action: The CoC is the NRC approved
design for each dry storage cask system. The proposed action would
grant Dominion a one-time exemption from the requirements of 10 CFR
72.212(b)(3) and from the portion of 72.212(b)(11) that states the
licensee shall comply with the terms, conditions, and specifications of
the CoC, to the extent necessary to enable Dominion to continue storage
of the seven DSCs in their current condition at the ISFSI associated
with North Anna Power Station Units 1 and 2. These regulations
specifically require storage of spent nuclear fuel under a general
license in dry storage casks approved under the provisions of 10 CFR
part 72, and compliance with the terms and conditions set forth in the
CoC for each dry spent fuel storage cask used by an ISFSI general
licensee.
The TN NUHOMS[supreg] HD dry cask storage system CoC provides
requirements, conditions and operating limits in Attachment A,
Technical Specifications (TS). The TS restrict the decay heat in lower
Zone ``1a'' locations to <= 1.05 kW and the upper Zone ``1b'' locations to <= 0.8 kW. The applicant inadvertently reversed the upper and lower zones while preparing the DSC loading maps. This resulted in twelve fuel assemblies being loaded into seven DSCs (serial numbers DOM-32PTH- 004-C, -005-C, -007-C, -010-C, -013-C, -019-C and GBC-32PTH-011-C) with decay heat greater than specified in the CoC. The maximum decay heat of the misloaded fuel assemblies at the time of loading was 0.859 kW, which exceeded the Zone ``1b'' limit mentioned above by 59 watts. Currently, the twelve affected fuel assemblies have been in storage for a minimum of 1.3 years and have decayed to meet the required decay heat limits of the CoC. The proposed action would grant Dominion a one-time exemption from the requirements of 10 CFR 72.212(b)(3) and the portion of 72.212(b)(11) which requires compliance with the terms, conditions, and specifications of a CoC, in order to allow continued storage of the seven affected DSCs in their current condition. This exemption approval is only valid for DSCs with serial numbers DOM-32PTH-004-C, -005-C, - 007-C, -010-C, -013-C, -019-C and GBC-32PTH-011-C, at the North Anna Power Station ISFSI. [[Page 20439]] Need for the Proposed Action: Dominion requested this exemption in order to continue storage of seven as-loaded DSCs containing twelve fuel assemblies which exceeded the CoC decay heat limits at the time of loading. Dominion, with the assistance of TN, has provided an evaluation and thermal analysis which shows that the affected DSCs remain bounded by the system's design basis limits and that the
continued storage of the fuel in the as-loaded configuration is safe.
Dominion has considered an alternative to the proposed action,
which would correct the condition by reloading the affected DSCs to be
in compliance with CoC No. 1030. This would involve retrieving each of
the DSCs from their Horizontal Storage Modules (HSM), unloading the
spent fuel assemblies from the DSC, performing inspections of various
DSC components, reloading the spent fuel assemblies into the used DSC
or a new DSC (if there was damage noted on the used DSC) in accordance
with CoC No. 1030, performing the DSC closing procedures, and
transferring the DSC back to the ISFSI for re-insertion into the HSM.
Dominion estimates this alternative action of loading and unloading
operations would increase personnel exposures by 250 mRem per affected
DSC. In addition, Dominion states the alternative to the proposed
action would generate radioactive contaminated material and waste
during loading and unloading operations and disposal of the used DSCs
if the DSCs were damaged during the unloading process. The licensee
estimates the alternative to the proposed action would cost an
estimated $300,000 for unloading and reloading operations of each
affected DSC and also necessitate additional fuel handling operations.
If the DSC was damaged during unloading, the licensee estimates an
additional $1,000,000 for purchase of a new DSC and $200,000 for
disposal of the used DSC.
The proposed action is necessary to document the acceptability and
safety basis for storage of the DSCs in the as-loaded configuration,
thus precluding the need to unload the seven DSCs.
Environmental Impacts of the Proposed Action: The NRC staff has
determined that the proposed action would not endanger life or
property. The potential impact of using the NUHOMS[supreg] HD dry cask
storage system was initially presented in the Environmental Assessment
(EA) for the rulemaking to add the TN NUHOMS[supreg] HD Horizontal
Modular Storage System for Irradiated Nuclear Fuel to the list of
approved spent fuel storage casks in 10 CFR 72.214 (71 FR 25740, dated
May 2, 2006 (Direct Final Rule), and 71 FR 71463, dated December 11,
2006 (Final Rule)).
The licensee submitted TN Calculation No. 10494-174, which
performed bounding thermal analysis using ANSYS finite element software
to evaluate the misloading events. The licensee concluded the maximum
fuel cladding temperature for the as loaded DSCs remained below the
fuel cladding temperature limit used in the Updated Safety Analysis
Report dated October 2, 2009. The NRC staff performed an independent
safety evaluation of the proposed exemption and determined that loading
of the spent nuclear fuel with higher than allowable decay heat loads
did not exceed the structural and shielding design basis and that the
fuel cladding temperatures are below the temperature limit at the time
of loading. The fuel assemblies have since decayed to meet the CoC
limits. There are no changes being made in the types or amounts of any
radiological effluents that may be released offsite, and there is no
significant increase in occupational or public radiation exposure as a
result of the proposed activities. Therefore, there are no significant
radiological environmental impacts associated with the proposed action.
The proposed action only affects the requirements associated with the
fuel assemblies already loaded into the casks and does not affect non-
radiological plant effluents, or any other aspects of the environment.
Therefore, there are no significant non-radiological impacts associated
with the proposed action.
Accordingly, the Commission concludes that there are no significant
environmental impacts associated with the proposed action.
Alternative to the Proposed Action: Because there is no significant
environmental impact associated with the proposed action, alternatives
with equal or greater environmental impact were not evaluated. As an
alternative to the proposed action, the NRC staff considered denial of
the proposed action which would involve reloading the affected DSCs as
described previously. Denial of the exemption would result in an
increase in radiological exposure to workers, a small potential for
radioactive releases to the environment due to radioactive material
handling, additional opportunities for accidents, and increased cost to
the licensee. Therefore, the NRC staff has determined that approving
the proposed action has a lesser environmental impact than denying the
proposed action.
Agencies and Persons Consulted: The environmental assessment
associated with this exemption request was sent to Ms. Ellie Irons of
the Virginia Department of Environmental Quality in the Office of
Environmental Impact Review, by letter dated November 14, 2011
(ML113180477). The state response was received by a letter dated
December 14, 2011 (ML120030312). The letter states that the proposed
action is unlikely to have significant effects on ambient air quality,
historic resources, surface waters, and wetlands. The letter also
states that it is unlikely to adversely affect species of plants or
insects listed by state agencies as rare, threatened, or endangered.
Furthermore, the Virginia Department of Health considered the
alternative to the proposed action of reloading the casks presents
several risks, namely additional radiation exposure to workers and
potential accidents that may lead to dispersal of radiation to the
environment. Thus, the Virginia Department of Health states that it
supports the exemption without reservation. The NRC staff has
determined that a consultation under Section 7 of the Endangered
Species Act is not required because the proposed action will not affect
listed species or a critical habitat. The NRC staff has also determined
that the proposed action is not a type of activity having the potential
to cause effects on historic properties. Therefore, no consultation is
required under Section 106 of the National Historic Preservation Act.
III. Finding of No Significant Impact
The environmental impacts of the proposed action have been reviewed
in accordance with the requirements set forth in 10 CFR Part 51. Based
upon the foregoing Environmental Assessment, the Commission finds that
the proposed action of granting the one-time exemption from the
requirements of 10 CFR 72.212(b)(3) and the portion of 72.212(b)(11)
which requires compliance with the terms, conditions, and
specifications of the CoC in order to allow Dominion to store spent
fuel assemblies in DSCs with serial numbers DOM-32PTH-004-C, -005-C, -
007-C, -010-C, -013-C, -019-C and GBC-32PTH-011-C in the as-loaded
configuration at the ISFSI associated with North Anna Power Station
Units 1 and 2, will not significantly impact the quality of the human
environment. Accordingly, the Commission has determined that an
environmental impact statement for the proposed exemption is not
warranted and that a finding of no significant impact is appropriate.
[[Page 20440]]
IV. Further Information
In accordance with 10 CFR 2.390 of NRC's ``Rules of Practice,'' final NRC records and documents regarding this proposed action are publicly available in the records component of NRC's Agencywide
Documents Access and Management System (ADAMS). The request for
exemption dated July 21, 2011 (ML11208C453), as supplemented September
28, 2011 (ML11286A143), was docketed under 10 CFR 50, Docket Nos. 50-
338 and 50-339, and under 10 CFR 72, Docket No. 72-56. These documents
may be inspected at NRC's Public Electronic Reading Room at http://www.nrc.gov/reading-rm/adams.html.
These documents may also be viewed electronically on the public computers
located at the NRC's Public Document Room (PDR), O1F21, One White Flint
North, 11555 Rockville Pike, Rockville, MD 20852. The PDR reproduction
contractor will copy documents for a fee. Persons who do not have access
to ADAMS, or who encounter problems in accessing the documents located
in ADAMS, should contact the NRC PDR Reference staff by telephone at
1-800-397-4209, or (301) 415-4737, or by email to pdr@nrc.gov.
For the Nuclear Regulatory Commission.
Dated at Rockville, Maryland, this 26th day of March, 2012.
Jennie Rankin,
Project Manager, Licensing Branch, Division of Spent Fuel Storage and
Transportation, Office of Nuclear Material Safety and Safeguards.
[FR Doc. 2012-8114 Filed 4-3-12; 8:45 am]
BILLING CODE 7590-01-P
[Federal Register Volume 77, Number 65 (Wednesday, April 4, 2012)]
[Notices]
[Pages 20440-20442]
From the Federal Register Online via the Government Printing Office [www.gpo.gov]
[FR Doc No: 2012-8111]
-----------------------------------------------------------------------
NUCLEAR REGULATORY COMMISSION
[Docket Nos. 72-1030, 72-55, 50-280 and 50-281; NRC-2012-0085]
Independent Spent Fuel Storage Installation, Virginia Electric
and Power Company, Surry Power Station Units 1 and 2
AGENCY: Nuclear Regulatory Commission.
ACTION: Issuance of an environmental assessment and finding of no
significant impact.
-----------------------------------------------------------------------
FOR FURTHER INFORMATION CONTACT: Jennie Rankin, Project Manager,
Division of Spent Fuel Storage and Transportation, Office of Nuclear
Material Safety and Safeguards, U.S. Nuclear Regulatory Commission,
Washington, DC 20555. Telephone: (301) 492-3268; Fax number: (301) 492-
3342; email: jennivine.rankin@nrc.gov.
SUPPLEMENTARY INFORMATION:
I. Introduction
The Nuclear Regulatory Commission (NRC or Commission) is
considering issuance of a one-time exemption to Virginia Electric and
Power Company (Dominion or licensee) pursuant to 10 CFR 72.7 from the
requirements of 10 CFR 72.212(b)(3) and the portion of 72.212(b)(11)
which requires compliance with the terms, conditions, and
specifications of the CoC. Dominion submitted its exemption request by
letter dated July 21, 2011, as supplemented September 28, 2011.
Dominion has loaded spent nuclear fuel into Transnuclear, Inc. (TN)
NUHOMS[supreg] HD Storage System (HD-32PTH) dry storage casks, under
the Certificate of Compliance (CoC or Certificate) No. 1030, Amendment
No. 0. The licensee inadvertently reversed the upper and lower zones
while preparing the dry shielded canister (DSC) loading maps. This
resulted in five fuel assemblies being loaded into four DSCs with decay
heat greater than the levels specified in the CoC. Dominion requests a
one-time exemption to the 10 CFR Part 72 requirements to continue
storage of the affected DSCs with serial numbers DOM-32PTH-001-C, -002-
C, -003-C, and -009-C in their current condition at the Independent
Spent Fuel Storage Installation (ISFSI) associated with the operation
of Dominion's nuclear power reactors, Surry Power Station Units 1 and
2, located in Surry County, Virginia.
II. Environmental Assessment (EA)
Identification of Proposed Action: The CoC is the NRC approved
design for each dry storage cask system. The proposed action would
grant Dominion a one-time exemption from the requirements of 10 CFR
72.212(b)(3) and from the portion of 72.212(b)(11) that states the
licensee shall comply with the terms, conditions, and specifications of
the CoC, to the extent necessary to enable Dominion to continue storage
of the four DSCs in their current condition at the ISFSI associated
with Surry Power Station Units 1 and 2. These regulations specifically
require storage of spent nuclear fuel under a general license in dry
storage casks approved under the provisions of 10 CFR part 72, and
compliance with the terms and conditions set forth in the CoC for each
dry spent fuel storage cask used by an ISFSI general licensee.
The TN NUHOMS[supreg] HD dry cask storage system CoC provides
requirements, conditions and operating limits in Attachment A,
Technical Specifications (TS). The TS restrict the decay heat in lower
Zone ``1a'' locations to <= 1.05 kW and the upper Zone ``1b'' locations to <= 0.8 kW. The applicant inadvertently reversed the upper and lower zones while preparing the DSC loading maps. This resulted in five fuel assemblies being loaded into four DSCs (serial numbers DOM-32PTH-001-C, -002-C, -003-C, and -009-C) with decay heat greater than specified in the CoC. The maximum decay heat of the misloaded fuel assemblies at the time of loading was 0.806 kW, which exceeded the Zone ``1b'' limit mentioned above by six watts. Currently, the five affected fuel assemblies have been in storage for a minimum of 2.5 years and have decayed to meet the required decay heat limits of the CoC. The proposed action would grant Dominion a one-time exemption from the requirements of 10 CFR 72.212(b)(3) and the portion of 72.212(b)(11) which requires compliance with the terms, conditions, and specifications of a CoC, in order to allow continued storage of the four affected DSCs in their current condition. This exemption approval is only valid for DSCs with serial numbers DOM-32PTH-001-C, -002-C, - 003-C, and -009-C, at the Surry Power Station ISFSI. Need for the Proposed Action: Dominion requested this exemption in order to continue storage of four as-loaded DSCs containing five fuel assemblies which exceeded the CoC decay heat limits at the time of loading. Dominion, with the assistance of TN, has provided an evaluation and thermal analysis which shows that the affected DSCs remain bounded by the system's design basis limits and that the
continued storage of the fuel in the as-loaded configuration is safe.
Dominion has considered an alternative to the proposed action,
which would correct the condition by reloading the affected DSCs to be
in compliance with CoC No. 1030. This would involve retrieving each of
the DSCs from their Horizontal Storage Modules (HSM), unloading the
spent fuel assemblies from the DSC, performing inspections of various
DSC components, reloading the spent fuel assemblies into the used DSC
or a new DSC (if there was damage noted on the used DSC) in accordance
with CoC No. 1030, performing the DSC closing procedures, and
transferring the DSC back to the ISFSI for re-insertion into the HSM.
Dominion estimates this alternative action of loading and unloading
operations would increase personnel exposures by 250 mRem per affected
DSC. In addition, Dominion states the alternative to the proposed
action would generate radioactive contaminated
[[Page 20441]]
material and waste during loading and unloading operations and disposal
of the used DSCs if the DSCs were damaged during the unloading process.
The licensee estimates the alternative to the proposed action would
cost an estimated $300,000 for unloading and reloading operations of
each affected DSC and also necessitate additional fuel handling
operations. If the DSC was damaged during unloading, the licensee
estimates an additional $1,000,000 for purchase of a new DSC and
$200,000 for disposal of the used DSC.
The proposed action is necessary to document the acceptability and
safety basis for storage of the DSCs in the as-loaded configuration,
thus precluding the need to unload the four DSCs.
Environmental Impacts of the Proposed Action: The NRC staff has
determined that the proposed action would not endanger life or
property. The potential impact of using the NUHOMS[supreg] HD dry cask
storage system was initially presented in the Environmental Assessment
(EA) for the rulemaking to add the TN NUHOMS[supreg] HD Horizontal
Modular Storage System for Irradiated Nuclear Fuel to the list of
approved spent fuel storage casks in 10 CFR 72.214 (71 FR 25740, dated
May 2, 2006 (Direct Final Rule), and 71 FR 71463, dated December 11,
2006 (Final Rule)).
The licensee submitted TN Calculation No. 10494-174, which
performed bounding thermal analysis using ANSYS finite element software
to evaluate the misloading events. The licensee concluded the maximum
fuel cladding temperature for the as loaded DSCs remained below the
fuel cladding temperature limit used in the Updated Safety Analysis
Report dated October 2, 2009. The NRC staff performed an independent
safety evaluation of the proposed exemption and determined that loading
of the spent nuclear fuel with higher than allowable decay heat loads
did not exceed the structural and shielding design basis and that the
fuel cladding temperatures are below the temperature limit at the time
of loading. The fuel assemblies have since decayed to meet the CoC
limits. There are no changes being made in the types or amounts of any
radiological effluents that may be released offsite, and there is no
significant increase in occupational or public radiation exposure as a
result of the proposed activities. Therefore, there are no significant
radiological environmental impacts associated with the proposed action.
The proposed action only affects the requirements associated with the
fuel assemblies already loaded into the casks and does not affect non-
radiological plant effluents, or any other aspects of the environment.
Therefore, there are no significant non-radiological impacts associated
with the proposed action.
Accordingly, the Commission concludes that there are no significant
environmental impacts associated with the proposed action.
Alternative to the Proposed Action: Because there is no significant
environmental impact associated with the proposed action, alternatives
with equal or greater environmental impact were not evaluated. As an
alternative to the proposed action, the NRC staff considered denial of
the proposed action which would involve reloading the affected DSCs as
described previously. Denial of the exemption would result in an
increase in radiological exposure to workers, a small potential for
radioactive releases to the environment due to radioactive material
handling, additional opportunities for accidents, and increased cost to
the licensee. Therefore, the NRC staff has determined that approving
the proposed action has a lesser environmental impact than denying the
proposed action.
Agencies and Persons Consulted: The environmental assessment
associated with this exemption request was sent to Ms. Ellie Irons of
the Virginia Department of Environmental Quality in the Office of
Environmental Impact Review, by letter dated November 14, 2011
(ML113180499). The state response was received by letter dated December
14, 2011 (ML120030312). The letter states that the proposed action is
unlikely to have significant effects on ambient air quality, historic
resources, surface waters, and wetlands. The letter also states that it
is unlikely to adversely affect species of plants or insects listed by
state agencies as rare, threatened, or endangered. Furthermore, the
Virginia Department of Health considered the alternative to the
proposed action of reloading the casks presents several risks, namely
additional radiation exposure to workers and potential accidents that
may lead to dispersal of radiation to the environment. Thus, the
Virginia Department of Health states that it supports the exemption
without reservation. The NRC staff has determined that a consultation
under Section 7 of the Endangered Species Act is not required because
the proposed action will not affect listed species or a critical
habitat. The NRC staff has also determined that the proposed action is
not a type of activity having the potential to cause effects on
historic properties. Therefore, no consultation is required under
Section 106 of the National Historic Preservation Act.
III. Finding of No Significant Impact
The environmental impacts of the proposed action have been reviewed
in accordance with the requirements set forth in 10 CFR part 51. Based
upon the foregoing Environmental Assessment, the Commission finds that
the proposed action of granting the one-time exemption from the
requirements of 10 CFR 72.212(b)(3) and the portion of 72.212(b)(11)
which requires compliance with the terms, conditions, and
specifications of the CoC in order to allow Dominion to store spent
fuel assemblies in DSCs with serial numbers DOM-32PTH-001-C, -002-C, -
003-C, and -009-C in the as-loaded configuration at the ISFSI
associated with Surry Power Station Units 1 and 2, will not
significantly impact the quality of the human environment. Accordingly,
the Commission has determined that an environmental impact statement
for the proposed exemption is not warranted and that a finding of no
significant impact is appropriate.
IV. Further Information
In accordance with 10 CFR 2.390 of NRC's ``Rules of Practice,'' final NRC records and documents regarding this proposed action are publicly available in the records component of NRC's Agencywide
Documents Access and Management System (ADAMS). The request for
exemption dated July 21, 2011 (ML11208B629), as supplemented September
28, 2011 (ML11286A115), was docketed under 10 CFR part 50, Docket Nos.
50-280 and 50-281, and under 10 CFR 72, Docket No. 72-55. These
documents may be inspected at NRC's Public Electronic Reading Room at http://www.nrc.gov/reading-rm/adams.html.
These documents may also be viewed electronically on the public computers
located at the NRC's Public Document Room (PDR), O1F21, One White Flint
North, 11555 Rockville Pike, Rockville, MD 20852. The PDR reproduction
contractor will copy documents for a fee. Persons who do not have access
to ADAMS, or who encounter problems in accessing the documents located
in ADAMS, should contact the NRC PDR Reference staff by telephone at
1-800-397-4209, or (301) 415-4737, or by email to pdr@nrc.gov.
Dated at Rockville, Maryland, this 26th day of March, 2012.
[[Page 20442]]
For the Nuclear Regulatory Commission.
Jennie Rankin,
Project Manager, Licensing Branch, Division of Spent Fuel Storage and
Transportation, Office of Nuclear Material Safety and Safeguards.
[FR Doc. 2012-8111 Filed 4-3-12; 8:45 am]
BILLING CODE 7590-01-P
|